Tech Support - HID LED G3 Lamp (Vertical)

Can HID LED G3 lamp operate directly off of line voltage (AC Main)?
Yes, Lunera HID LED G3 can be bypassed to operate in voltage range of 120VAC to 277VAC. Do NOT install HID LED G3 into line voltage above 277VAC. ...
Thu, 10 Nov, 2016 at 2:16 PM
Ballast Compatibility - HID LED G3
Lunera HID LED G3 and 360 supports operation with CWA MH and HPS ballasts. The following CWA wattages are compatible with HID LED G3 lamps: ...
Thu, 10 Nov, 2016 at 2:46 PM
Can HID LED G3 lamps be installed with dimmers?
Lunera has discontinued dimming capability with our HID LED G3 products due to the increased likelihood of incompatibility related problems as well as a d...
Fri, 9 Feb, 2018 at 11:27 AM
Can HID LED G3 lamps be installed into fully enclosed fixtures?
Yes, Lunera HID LED G3 lamps are designed to be operable in enclosed fixtures.  Passive cooling, active cooling, and reduced power methods are de...
Fri, 11 Nov, 2016 at 8:29 AM
Does HID LED G3 lamp support operation with 347V / 480V?
For line driven (ballast bypass) option, the lamp does NOT support 347V or 480V. A step-down transformer must be installed to lower the input voltage to ...
Fri, 11 Nov, 2016 at 8:34 AM
Are Lunera HID LED G3 lamps DLC listed?
Yes, mogul base (E39) HID LED G3 lamps are listed on DLC's qualified product list.  Medium base (E26) HID LED G3 lamps are listed on LDL's...
Fri, 11 Nov, 2016 at 8:38 AM
Do Lunera HID LED G3 lamps qualify for rebates?
Utility companies that are DLC's member offer custom or prescriptive rebates to Lunera HID LED G3 lamps.  DLC only maintains a E39 line drive...
Fri, 11 Nov, 2016 at 9:14 AM